Computed radiography explained: from imaging plate to digital image

Follow a computed radiography example from imaging plate to reader and digital image. Then compare sample counts with demonstrated detail.

Follow the CR image chain

Computed radiography uses a storage-phosphor imaging plate. Exposure leaves a latent image in that plate; a separate reader uses laser stimulation to retrieve the stored response. The response is converted into digital image data for display on a workstation.

DÜRR NDT’s technical overview describes these stages. Naming the plate, reader and displayed image separately makes the sequence easier to study.

Sources: DÜRR NDT: how computed radiography works.

Connect readout terms to their roles

Carestream’s CR white paper describes photostimulable luminescence, or PSL: light stimulation releases a light response from the exposed phosphor. The reader collects and digitizes that response. A scanner or read-out unit is another name for the reader.

When making study notes, give each unfamiliar term both a name and a role. For example, put “reader” beside the readout stage. This helps you follow an explanation even when a second author uses different vocabulary.

Sources: Carestream: Computed Radiography 101, pages 3–4 and 8.

Separate scan pitch, laser spot and spatial resolution

Scan pitch, laser spot size and basic spatial resolution describe different aspects of a CR system.

  • A finer sampling grid alone does not establish improved spatial resolution. The imaging plate and reader also matter.
  • Keep a recorded setting separate from a demonstrated result when comparing classroom examples.
Three terms to keep separate in your CR study notes
TermWhat it describesUseful question
Scan pitch or sampling intervalThe spacing between samples collected during readout.How closely was the plate sampled?
Laser spot sizeThe area stimulated by the reader’s focused laser.Which laser spot was used with this plate?
Basic spatial resolutionThe system’s ability to distinguish fine detail.What measured evidence supports the claimed resolution?

Sources: DÜRR NDT: laser spot, sampling and CR image quality.

Try a sampling-grid study exercise

Two fictional classroom diagrams cover the same square area. Diagram A divides it into a 100 × 100 grid; diagram B uses 200 × 200. These are arithmetic examples, not scanner settings or inspection criteria.

  1. Calculate what changed: B has twice as many samples along each edge and four times as many overall.
  2. Check the proposed conclusion: “B must resolve a discontinuity half as small” does not follow from those counts alone.
  3. Write the missing question: “What plate, reader and measured resolution evidence accompany each example?”
Count the samples before making a resolution claim
DiagramGridSample count
A100 × 10010,000
B200 × 20040,000

Try a record-label matching exercise

Imagine one fictional lesson example with the four labels below. First read only the labels and write what each identifies. Then check the middle column and use the final column to extend your notes. These invented identifiers are for study, not a field record template.

  • Draw a line from P-A to R-A and another from R-A to I-A. Write one sentence describing each connection.
  • Now suppose S-A shows no image identifier. List the missing link you would ask the lesson author to supply.
  • Check your answer: a useful question names the saved image and the view represented by S-A. Similar-looking pictures alone do not supply that link.
Four labels in a fictional CR lesson example
LabelWhat it identifiesQuestion for your notes
Plate P-AThe imaging plateWhich object is being discussed?
Readout R-AThe documented reading of that plateWhich event connects the records?
Image I-AThe saved image in the exampleWhich image does the discussion concern?
Screenshot S-AA picture of the software displayWhich saved image and view does it show?

Choose training for the technique you are adding

NDT Academy’s CR Level II add-on is for film radiographers who already hold RT Level II. The syllabus includes CR workflow and photostimulable luminescence, reader and scanner architecture, and software topics covering original images and derived views.

The course provides formal training through lessons and equipment-familiarization simulations. It does not replace actual-system practicals or award employer certification. Confirm eligibility and your employer’s training plan before enrolling. The separate DR add-on focuses on digital detector array systems.

Sources and further reading

Sources checked on October 28, 2026. Follow the current requirements from your employer or certification body when planning qualification or an examination.